GUTTERMELT SR Performance Ratings & Output Curve
| Copper bus wire |
16 AWG |
| Nominal Power Output |
5, 9, or 12 Watts/Ft in iced water at 32ºF (0ºC) |
| Max Maintenance Temperature |
149ºF (65ºC) |
| Max intermittent exposure temperature |
212ºF (100ºC)
T rating: T5 |
| Voltage |
120, 208, 240, 277
or 480 VAC |
| Watts at 32°F (0°C) |
Up to Spec W per lin. ft. |
| Length |
Refer to product label |
| Diameter/Height |
Approx. 0.22” x 0.42” |
| Bending Radius |
Not tighter than 2” inside diameter |
| Minimum Spacing |
2” |
| Cap Thickness |
None Required
|
|
|
Click Here to use our GutterMelt Length Calculator |
| |
GutterMelt 5 W/ft
|
120V |
240V |
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F |
15A
300 ft
200 ft
180 ft |
20A
--
270 ft
230 ft |
30A
--
330 ft
330 ft |
40A
--
--
-- |
15A
660 ft
410 ft
360 ft |
20A
--
560 ft
480 ft |
30A
--
660 ft
660 ft |
40A
--
--
-- |
| |
| |
GutterMelt 9 W/ft
|
120V |
240V |
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F |
15A
150 ft
95 ft
85 ft |
20A
200 ft
125 ft
100 ft |
30A
210 ft
190 ft
170 ft |
30A
210 ft
190 ft
170 ft |
15A
295 ft
195 ft
170 ft |
20A
390 ft
250 ft
225 ft |
30A
420ft
375 ft
340 ft |
40A
--
420 ft
420 ft |
| |
| |
GutterMelt 12 W/ft
|
120V |
240V |
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F |
15A
115 ft
70 ft
60 ft |
20A
150 ft
95 ft
85 ft |
30A
180 ft
145 ft
120 ft |
40A
--
180 ft
165 ft |
15A
230 ft
150 ft
130 ft |
20A
305 ft
200 ft
175 ft |
30A
360 ft
300 ft
260 ft |
40A
--
360 ft
360 ft |
| |